<?xml-stylesheet type="text/css" media="screen" href="//cdn.nexternal.com/styles/rsscontent.css"?>
<rss version="2.0">
  <channel>
    <title>Texas Scientific Products - Autosamplers / HTA Autosamplers / All Products</title>
    <copyright>Copyright 2026, Texas Scientific Products</copyright>
    <description>&lt;div&gt;Our comprehensive product range includes autosampler solutions for several spectroscopy applications. We offer automation for ICP-OES (also referred to as ICP-AES or ICP plasma), ICP-MS, MP-AES and Flame Atomic Absorption.&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;img src="https://cdn.nexternal.com/tsp/images/htalogo.png" border="0" /&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;b&gt;Why HTA AUTOSAMPLERS?&lt;/b&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;HTA Autosamplers feature straight forward functionality and extremely high productivity. The optimized layout - including a sample carousel convenient for your lab routine - allows to &lt;b&gt;save bench space&lt;/b&gt;, while the short flow-path implies &lt;b&gt;shorter rinse time&lt;/b&gt;. Smart next-generation electronics and intuitive user interface leads to a &lt;b&gt;superior user experience&lt;/b&gt;.&lt;/div&gt;</description>
    <link>https://www.txscientific.com/hta-autosamplers-c210all.aspx</link>
    <pubDate>Sun, 25 Oct 2026 09:04:25 GMT</pubDate>
    <ttl>60</ttl>
    <generator>Nexternal RSS 2.0</generator>
    <language>en-us</language>
    <item>
      <link>https://www.txscientific.com/ht1200i-high-capacity-icpaa-autosampler-p2451.aspx</link>
      <guid isPermaLink="false">Product2451</guid>
      <pubDate>Thu, 25 Jul 2024 14:20:41 GMT</pubDate>
      <title>HT1200I High Capacity ICP/AA Autosampler</title>
      <description>&lt;div style="float:left"&gt;&lt;a class="url" href="https://www.txscientific.com/ht1200i-high-capacity-icpaa-autosampler-p2451.aspx"&gt;&lt;img src="//cdn.nexternal.com/tsp/images/HT1200I_p2451_t_p1_z75.png"  alt="HT1200I High Capacity ICP/AA Autosampler" border="0" hspace="3"&gt;&lt;/a&gt;&lt;/div&gt;&lt;span class="riRssTitle"&gt;&lt;a href="https://www.txscientific.com/ht1200i-high-capacity-icpaa-autosampler-p2451.aspx"&gt;HT1200I High Capacity ICP/AA Autosampler&lt;/a&gt;&lt;/span&gt;&lt;br&gt;&lt;a href="https://www.txscientific.com/ht1200i-high-capacity-icpaa-autosampler-p2451.aspx"&gt;Buy Now:&lt;/a&gt; &lt;span color="#990000"&gt;&lt;b&gt;$1,000.00&lt;/b&gt;&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;div&gt;&lt;div&gt;The&lt;b&gt; HT1200I&lt;/b&gt; holds three sample racks. Each rack has a consistent capacity to reach a remarkable total number of samples. Conventional tube racks are supported to accommodate a wide range of sample tubes.&amp;nbsp; Furthermore, custom racks can be integrated to accommodate custom sample vessels.&lt;/div&gt;&lt;div&gt;&lt;ul&gt;&lt;li&gt;Number of Removable High Capacity Racks (3)&lt;/li&gt;&lt;li&gt;Max Quantity of Tubes (189)&lt;/li&gt;&lt;li&gt;Tube Type (10mL, 50mL or any other shape or size)&lt;/li&gt;&lt;li&gt;Rinse Station - Included&lt;/li&gt;&lt;li&gt;Peristaltic Pump - Included&lt;/li&gt;&lt;li&gt;Shortest sample rinse time&lt;/li&gt;&lt;li&gt;Fastest cleaning&lt;/li&gt;&lt;li&gt;Reduced bench space&lt;/li&gt;&lt;/ul&gt;&lt;div&gt;&lt;b&gt;Suitable for the following ICP and AA Manufacturers&lt;/b&gt;:&amp;nbsp; Agilent, Analytic Jena, Perkin Elmer, Thermo, Shimadzu, Spectro&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;/div&gt;&lt;div&gt;&lt;b&gt;HIGH PRODUCTIVITY AND FLEXIBILITY&amp;nbsp;&lt;/b&gt;&lt;/div&gt;&lt;div&gt;The HT1200I holds three sample racks. Each rack has a consistent capacity to reach a remarkable total number of samples. Conventional tube racks are supported to accommodate a wide range of sample tubes.&amp;nbsp; Furthermore, custom racks can be integrated to accommodate custom sample vessels.&lt;/div&gt;&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;div&gt;&lt;b&gt;ENJOY SEALED SAMPLE AND SOLVENT TUBES&lt;/b&gt;&amp;nbsp;&lt;/div&gt;&lt;div&gt;Aggressive chemicals used for atomic spectroscopy applications lead to corrosion and unpleasant odors. In the past, autosampler enclosures have been used to address these issues. However, they offer a partial solution: they do not limit corrosion stress on the autosampler, they are quite expensive and they do not always fit available spaces on the bench.&lt;/div&gt;&lt;div&gt;&amp;nbsp;&lt;/div&gt;&lt;div&gt;The &lt;b&gt;HT1200I&lt;/b&gt; model offers the definitive answer to corrosion and bad smell by supporting &lt;i&gt;&lt;b&gt;sealed samples and reagent tubes&lt;/b&gt;&lt;/i&gt;. The usage of sealed tubes helps to reduce the amount of chemical vapours in the environment, improve the quality of lab air and increase the lifetime of any object that could be affected by corrosion&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;The &lt;b&gt;HT1200I&lt;/b&gt; model is the first and only ICP autosampler to support sealed sample and reagent tubes.&lt;/div&gt;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;Visit &lt;a href="https://www.txscientific.com/hta-autosamplers-c210all.aspx"&gt;HTA Autosamplers&lt;/a&gt; to see additional products in this category.&lt;/div&gt;</description>
    </item>
    <item>
      <link>https://www.txscientific.com/ht1000i-series-icpaa-autosampler-p2450.aspx</link>
      <guid isPermaLink="false">Product2450</guid>
      <pubDate>Wed, 24 Jul 2024 05:32:04 GMT</pubDate>
      <title>HT1000I Series ICP/AA Autosampler</title>
      <description>&lt;div style="float:left"&gt;&lt;a class="url" href="https://www.txscientific.com/ht1000i-series-icpaa-autosampler-p2450.aspx"&gt;&lt;img src="//cdn.nexternal.com/tsp/images/HT1000_p2450_t_p1_z75.png"  alt="HT1000I Series ICP/AA Autosampler" border="0" hspace="3"&gt;&lt;/a&gt;&lt;/div&gt;&lt;span class="riRssTitle"&gt;&lt;a href="https://www.txscientific.com/ht1000i-series-icpaa-autosampler-p2450.aspx"&gt;HT1000I Series ICP/AA Autosampler&lt;/a&gt;&lt;/span&gt;&lt;br&gt;&lt;a href="https://www.txscientific.com/ht1000i-series-icpaa-autosampler-p2450.aspx"&gt;Buy Now:&lt;/a&gt; &lt;span color="#990000"&gt;&lt;b&gt;$6,500.00&lt;/b&gt;&lt;/span&gt; &lt;br /&gt;&lt;br /&gt;&lt;div&gt;&lt;div&gt;&lt;div&gt;The &lt;b&gt;HT1100I&lt;/b&gt; model includes a peristaltic pump, which can directly&lt;/div&gt;&lt;div&gt;manage the aspiration of the liquid required for probe cleaning.&amp;nbsp;&amp;nbsp;&lt;/div&gt;&lt;div&gt;If the ICP or AA already contains a pump with a channel for probe purging, the HT1000I model is a perfect.&lt;/div&gt;&lt;div&gt;&lt;ul&gt;&lt;li&gt;Number of Removable Racks (6)&lt;/li&gt;&lt;li&gt;Max Quantity of Tubes (89)&lt;/li&gt;&lt;li&gt;Tube Type (10mL or 50mL)&lt;/li&gt;&lt;li&gt;Rinse Station Included&lt;/li&gt;&lt;li&gt;Shortest sample rinse time&lt;/li&gt;&lt;li&gt;Fastest cleaning&lt;/li&gt;&lt;li&gt;Reduced bench space&lt;/li&gt;&lt;/ul&gt;&lt;div&gt;&lt;b&gt;Suitable for the following ICP and AA Manufacturers&lt;/b&gt;:&amp;nbsp; Agilent, Analytic Jena, Perkin Elmer, Thermo, Shimadzu, Spectro&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;/div&gt;&lt;div&gt;&lt;b&gt;OPTIMIZED LAYOUT&lt;/b&gt;&lt;/div&gt;&lt;/div&gt;&lt;div&gt;When you look at autosamplers, automatic sample changers or any other automation equipment, the larger it is, the more expensive it is. By surveying labs in many countries, we have sized the HT1000I series to offer enough sample capacity to satisfy the needs of a standard lab. Oversized instruments lead to oversized costs: at the initial purchase, during operations – due to usage of long transfer line – and at maintenance – being more expensive to care about. Therefore, choosing the correct size is the best way to optimise your total cost of ownership.&lt;/div&gt;&lt;div&gt;&lt;br /&gt;&lt;/div&gt;&lt;div&gt;&lt;b&gt;CONTINUOUS SAMPLE FEEDING&lt;/b&gt;&lt;/div&gt;&lt;div&gt;The sample carousel is organized in six racks, each of which may run a different type or shape of sample tubes. You may designate one rack for standards and control samples using large 50ml tubes, while using smaller tubes in the other racks to maximise capacity. Racks are removable to support off-instrument sample preparation and continuous sample feeding. Furthermore, the racks are recognized so that a mismatch is not possible (e.g., putting rack #2 in the position of rack #3) to comply with the best lab practices.&amp;nbsp;&lt;/div&gt;&lt;br /&gt;&lt;br /&gt;Visit &lt;a href="https://www.txscientific.com/hta-autosamplers-c210all.aspx"&gt;HTA Autosamplers&lt;/a&gt; to see additional products in this category.&lt;/div&gt;</description>
    </item>
  </channel>
</rss>